It is suitable for electrical performance testing of monocrystalline silicon, polycrystalline silicon, Topcon, HIT, HJT, IBC, thin-film cells, and other photovoltaic modules.
Acceptable test parameters | I- V, P-V curve, short-circuit current Isc, open-circuit voltage Voc, maximum power Pmpp, battery efficiency Eff, fill factor FF, maximum power point current Impp, II- |
---|---|
Panel size | 2600mm×1600mm |
Test speed | 240 pcs/H |
Flash time | 10-150ms adjustable |
Lamp life | >100000次 / 10ms |
Irradiance range | 300-1200W/㎡ |
Spectral matching | 0.875-1.125(A+ grade) |
Irradiance instability STI | ≤0.25%(A+Grade) |
Irradiance instability LTI | ≤1%(A+Grade) |
Irradiance non-uniformity | ≤1%(A+Grade) |
Spectral range | (IEC 60904-9:2020) 300-1200nm |
Repeatable test accuracy | <0.3% |
Test resolution | 16bit (measurement resolution 0.003%) |
Lamp type | Straight tube xenon lamp |
Way of working | Single pulse |
Voltage | 200-240V, 10A, 50/60HZ, single phase |
Machine size | Light source box (length x width x height): 2900x1800x1050mm Electrical control cabinet (length x width x height): 800x600x1800mm |
Weight | Light source box: 0.5 tons; electric control cabinet: 0.28 tons |