AAA standards and Higher than IEC60904-9 standard
Full spectrum: 300~1200nm, spectrum extended to 1800nmLong pulse: 15~200ms (adjustable)
Top lighting/side lighting
300-1200nm full spectrum: more truly reflects the solar module’s response capability in each band
Electronic load: The scanning direction supports two modes: Isc→Voc and Voc→Isc.
Measurement objects: silicon-based thin film components, cadmium telluride, perovskite, crystalline silicon and other technical components
Capacity | <45s(100ms) |
---|---|
Maximum measurable area | 3500×2500mm |
Light source direction | Uplighting light source |
Feeding method | On-line Auto conveyor |
Solar simulator source level | AAA |
Solar simulator standards | IEC 60904-9 |
Calibration method | Standard solar panel automatically calibrate light intensity in one go |
Spectral matching | 0.75-1.25 (Grade A) |
illuminance instability | <0.5% (Grade A) |
illuminance non-uniformity | <2% (Grade A) |
Spectral range | 10-200ms |
Flash time | 10-200ms |
Irradiance range | 200-1200W/m² |
ISC 60 times repeatability | <0.2% |
Light source life | ≥15W times(100ms) |
Measuring range | Voltage: 100-600V (resolution 1mV) Current: 0-10A (resolution 1mA) |
Test parameters | Isc,Voc,Pmax,Vm,Im,FF,EFF,Temp,Rs,Rsh |
Measure power | 3000W(Max) |
Test wiring method | Four wire system |
Software Function | Supports code scanning gun trigger test, supports test data saving, query, and export, supports voice broadcast of test results, supports foot pedal trigger, and has automatic temperature compensation |
Temperature | 25℃±10℃; |
Humidity | ≤85% |
Voltage | AC220V/50Hz/20A |
Machine size | 4630mm×4300mm×5630mm |
A. The YLP1000 series solar module tester has a direct light structure, simulating natural sunlight irradiation conditions. It can realize an uplighting installation mode according to the on-site environment, meeting the full spectrum of 300-1200nm, and the pulse width is adjustable from 10 to 200. The equipment meets the industry’s top spectral standards: 1. AAA performance; the three core performance indicators of non-uniformity, spectral matching, and light intensity stability all exceed industry standards. 2 Full spectrum; the spectrum range meets the range of 300-1200nm, enabling full-spectrum testing of high-efficiency crystalline silicon cells, and significantly improving test accuracy. The solar cell modules use four-wire connections and a high-speed data acquisition system to ensure the measurement accuracy of solar cell current. Infrared non-contact temperature measurement accurately measures component temperature, ensuring the accuracy of temperature correction.
B. Test objects: These are suitable for testing, recording, and exporting electrical performance parameters of silicon-based thin-film components, cadmium telluride, perovskite, crystalline silicon, and other technical elements.
Copyright © YiLi Pv Tech Ltd.
Opening Hours:
Monday – Friday 8am – 9pm
Mob&Whatsapp: +86 18813913430
Email: sales@yilipv.com
Address: Room 918,Building 2,Wujin Wanda Plaza,Wujin District, Changzhou City, Jiangsu Province,China